Independent Test Reports

Acoustic | Structural | Fire

Downloadable Acoustic and Fire Assemblies

Acoustic & Vibration Tests

Wall Assemblies
QuietRock 545THX

 STC 80, 545THX two layers on both sides of double wood studs

 STC 75, 545THX on both sides of double wood studs

 STC 60, 545THX on both sides of single wood studs

Wall Assemblies
QuietRock 525

 STC 70, QuietRock 525 with Area Separation Wall per UL U347

 STC 65, 525 on both sides of double wood studs

 STC 61, 525 on both sides of staggered wood studs

 STC 61, Type X over 525 on both sides of single 6” steel studs

 STC 61, 525 one side, Type X over 525 on other side of single 6” steel studs

 STC 59, 525 on both sides of single
6”  steel  studs


 STC 57, 525 on both sides of single steel studs

 STC 55, 525 on one side of single
6” steel studs


 STC 55, 525 on one side of single steel studs

 STC 55, 525 on both sides of single wood studs

 STC 51, 525 on one side of single wood studs

 STC 49, 525 retrofit on one side of single wood studs
 

Wall Assemblies
QuietRock 530

 STC 74, 2 Layers of 530 on both sides of double studs

 STC 66, 530 on both side of double wood studs

 STC 57, 2 Layers of 530, single wood studs, 1X QR530

 STC 56, 530 retrofit both sides of single wood stud wall

 STC 55, 530 on both sides of single steel studs

 STC 54, 530 on both sides of single wood studs

 STC 53, 530 retrofit on 1 side of standard wall

 STC 52, 530 in one side of single
wood studs

Wall Assemblies
QuietRock DensArmor Plus 528

 STC 58, 528 on both sides of single
steel studs


 STC 56, 528 on 1 side of single
steel studs


 STC 50, 528 on 1 side of single
wood studs

QuietRF Tests

 QuietRock 530RF - RF Shielding - IEEE 299

Back to Top

Wall Assemblies
QuietRock 510

 STC 69, QuietRock 510 with Area Separation Wall per UL U347

 STC 56, Type X over QuietRock 510 on one side, 2 layers of Type X other side of single steel studs

 STC 54, 5/8” Type X over QuietRock 510 on one side of single steel studs

 STC 52, QuietRock 510 on both sides of single wood studs

 STC 49, QuietRock 510 on 1 side of single wood studs

 STC 47, QuietRock 510 retrofit install

Wall Assemblies
QuietRock 516

 STC 49, 516 on both sides of 16” OC single wood studs

 STC 46, 516 on one side of 16” OC single wood studs

Wall Assemblies
QuietRock UltraSTEEL 527

 STC 65, 527 on both  sides of double UltraSTEEL studs

 STC 64, 527 on 1 side,  side of double UltraSTEEL studs

 STC 57, 527 over Type X on 1 side, 2 layers of Type X other side of single 2-1/2” UltraSTEEL studs

 STC 55, 527 on 1 side of single UltraSTEEL studs

QuietCoat 118 Acoustic Tests

 Dynamic Labs, applied to John Deere commercial lawn mower

 Ohio State University, applied to a standard steel plate #1

 Ohio State University, applied to a standard steel plate #2 full test data

 CTC-United Defense Labs, Loss factors over temperature

 Oberst Beam Test Results Peak material loss factor = 0.7

Floor/Ceiling STC & IIC Tests

 STC 53 | IIC 74 with carpet - Open Truss

 STC 58 | IIC 51 with hardwood - Open Truss

 STC 51 | IIC 64 with Carpet (without RC) - I-Joist

 STC 60 | IIC 70 with Carpet (with RC) - I-Joist

 STC 63 | IIC 59 with Hardwood (with RC) - I-Joist

 STC 65 | IIC 59 with Tile (with RC) - I-Joist

 IIC 63 with Tile (with ceiling) - Concrete

 IIC 63 with Hardwood (with ceiling) - Concrete

 IIC 48 | ∆IIC 20 with Tile (without ceiling) - Concrete

 IIC 54 | ∆IIC 26 with Hardwood (without ceiling) - Concrete

QuietShip, QuietBoat

 QuietShip X-Craft Acoustic Test

QuietHome Door

 Standard STC 44

 THX Certified STC 51

Structural Tests

QuietRock 525

 NTA ceiling sag test

QuietRock DensArmor Plus 528

 Abrasion, indentation, and impact tests

QuietRock 530

 NAHB Shear Wall Test

 Impact Test

Back to Top

QuietWood 631

 PSI Structural Load Tests

 NAHB Shear Diaphragm Test

QuietPad 420

 Robinson Floor Test ASTM C627

Fire Tests

QuietRock 525

 UL Fire Rating U386, W317

 UL Fire Rating U386

 Full scale ASTM E119 1-hour Fire Rating

QuietRock UltraSTEEL 527

 UL Fire Rating V463, V464, W460

 Full scale ASTM E119 1-hour Fire Rating
 

QuietRock DensArmor Plus 528

 UL Fire Test

QuietRock 530

 UL Fire Test

 UL Fire Rated Design U376

 UL Fire Rating Design U305

 UL Fire Rating Design U309

 UL Fire Rating Design U340

 UL Fire Rating Design U341

 ULC W313

 E84 Smoke & Flame Test

 UPITT Toxicity Test

Back to Top

QuietPutty

 UL 1479 Fire Test

Floor-Ceiling Assembly

 ASTM E119 1-hour Fire Rating

 UL 1-hour Fire Rating

QuietCoat, QuietCar, QuietTruck

 FMVSS302 Vehicle Fire Rating

QuietCoat, QuietAir

 FAR/FAA Fire Rating

QuietShip, QuietBoat

 Fire Performance

 Smoke and Toxicity

 IMO Fire Rating

 QuietShip X-Craft Test

ABS Approval (on-line)